Release Notes

Dell Update Packages do not require new refreshes of existing DUPs to be reinstalled since the
firmware or driver payload does not change when the DUP is refreshed. A new DUP is available if
changes have been made to the firmware or driver payload.
If the console terminal displays USB connection status messages, ignore them as they do not
affect the system.
On all versions of the ESX, the following the USB connection error messages are generated. These
messages can be ignored.
The following shows a typical message:
Vendor: iDRAC Model: MAS022 Rev: 1.00
Type: Direct-Access ANSI SCSI revision: 02
VMWARE SCSI Id: Supported VPD pages for sdc : 0x1f
VMWARE SCSI Id: Could not get disk id for sdc
VMWARE: Unique Device attached as scsi disk sdc at scsi3, channel 0, id 0, lun 0
Attached scsi removable disk sdc at scsi3, channel 0, id 0, lun 0
SCSI device sdc: 327680 512-byte hdwr sectors (168 MB)
sdc: Write Protect is on
SCSI disk error: host 3 channel 0 id 0 lun 0 return code = 8000002
Current sd08:21: sense key Data Protect
Additional sense indicates Write protected
I/O error: dev 08:21, sector 1
SCSI disk error: host 3 channel 0 id 0 lun 0 return code = 8000002
Current sd08:21: sense key Data Protect
Additional sense indicates Write protected
I/O error: dev 08:21, sector 1
Vendor: iDRAC Model: SECUPD Rev: 0329
Type: Direct-Access ANSI SCSI revision: 02
DUPs are designed to run only on a 32-bit environment. To run DUPs on a pure 64-bit environment,
use the Dell YUM repository.
If you attach VMedia on a system with the iDRAC Firmware version 1.5, some DUPs may fail to
work. To resolve this issue, run the following command:
racadm config -g cfgRacVirtual -o cfgLCDriveEnable 1 where cfgLCDriveEnable is an option
implemented in iDRAC 1.5 with a default of 0 (disabled)
NOTE: This command enables LCDrive from the iDRAC console or the OS. If the LCDrive is not
enabled, DUPs may not work.
After the DUP update is complete, to ensure the LCDrive is invisible, run the following command:
racadm config -g cfgRacVirtual -o cfgLCDriveEnable 0
When you run USC-related DUPs with Citrix Xenserver 5.6.0-x, you need to set the virtual media
in iDRAC to Detach. If you set the virtual media to Attach, the following error message is
displayed:
"Inventory Failure: Secure Copy Failure - The Secure copy function has failed"
For BIOS updates, the following message is displayed:
"doDepCheck failed"