White Papers
11 Standards-based storage management for Dell EMC PowerEdge servers
2. View storage controller RAID.Slot.6-1 for the detected drives attached to the controller.
C:\Python27>CreateVirtualDiskRedfish.py -ip 192.168.0.130 -u root -p calvin -d
RAID.Slot.6-1
- Drive(s) detected for RAID.Slot.6-1 –
Disk.Bay.7:Enclosure.Internal.0-1:RAID.Slot.6-1
Disk.Bay.9:Enclosure.Internal.0-1:RAID.Slot.6-1
Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.6-1
Disk.Bay.1:Enclosure.Internal.0-1:RAID.Slot.6-1
Disk.Bay.2:Enclosure.Internal.0-1:RAID.Slot.6-1
Disk.Bay.3:Enclosure.Internal.0-1:RAID.Slot.6-1
Disk.Bay.4:Enclosure.Internal.0-1:RAID.Slot.6-1
Disk.Bay.5:Enclosure.Internal.0-1:RAID.Slot.6-1
Disk.Bay.6:Enclosure.Internal.0-1:RAID.Slot.6-1
Disk.Bay.8:Enclosure.Internal.0-1:RAID.Slot.6-1
3. Create a RAID 0 VD composed of two physical drives, 10 GB each in size.
C:\Python27>CreateVirtualDiskRedfish.py -ip 192.168.0.130 -u root -p calvin -V y
-C RAID.Slot.6-1 -D Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.6-
1,Disk.Bay.1:Enclosure.Internal.0-1:RAID.Slot.6-1 -R 0 --size 10737418240
- PASS: POST command passed to create "NonRedundant" virtual disk, status code
202 returned
- PASS, "realtime" JID_264172337521 jid successfully created for create virtual
disk
- WARNING, JobStatus not completed, current status is: "New", precent completion
is: "0"
- WARNING, JobStatus not completed, current status is: "Job in progress.",
precent completion is: "1"
<Output edited for brevity…>
- WARNING, JobStatus not completed, current status is: "Job in progress.",
precent completion is: "99"
--- PASS, Final Detailed Job Status Results ---
JobState: Completed
Description: Job Instance
CompletionTime: 2018-05-15T15:48:39
PercentComplete: 100
StartTime: TIME_NOW
MessageId: PR19
Message: Job completed successfully.
EndTime: TIME_NA
Id: JID_264172337521
JobType: RealTimeNoRebootConfiguration
Name: Config:RAID:RAID.Slot.6-1