Administrator Guide
12 PowerEdge MX7000 Server Configuration using OME Modular
IOID112
The initiator properties of the
<Controller> Port <Port> are
successfully configured.
None.
IOID113
Unable to configure the initiator
properties of <Controller> Port
<Port>.
Make sure that the iSCSI or
FCoE partition of the network
port is enabled. Check
whether or not the network
controller is working and then
retry the operation.
IOID114
The target settings properties of
the <controller> Port <port> are
successfully configured.
None.
IOID115
Unable to configure the target
settings properties of the
<controller> Port <port>.
Make sure that the iSCSI or
FCoE partition of the network
port is enabled. Check
whether or not the network
controller is working.
IOID117
The operation to apply I/O Identity
settings based on current
persistence policy settings has
completed successfully.
None.
IOID118
Unable to configure some or all I/O
Identity settings based on current
persistence policy settings.
Review the previous log
entries and identify the
devices that did not
successfully complete
configuration operations. For
the identified devices, do the
following and then restart the
server: 1) Make sure the
device is installed properly. 2)
Make sure the device has
latest firmware installed. If the
issue persists, contact your
service provider.
- Slot Profile: Attaching a profile to a slot: Always attach a profile to the slot(s)
via the Chassis
→
Hardware
→
Chassis Slots wizard. Although the Configuration
→ Deploy → Deploy Template wizard can be used for attaching profiles to slots,
problems while selecting the “Device/Slot Selection” can be easily misunderstood
and lead to selecting occupied slots (via “Chassis_SVCTAG” under “All Devices”)
thus resulting in deployment as a “device profile”.
- Slot Profile: Occupied slot: If a slot is occupied with a server at the time of
attaching a profile to the slot via Chassis
→
Hardware
→
Chassis Slots wizard,