17 Standards-based NIC and FC-HBA management for Dell EMC PowerEdge servers
- PASS, Command passed to power ON server, code return is 204
- WARNING, JobStatus not completed, current status is: "Task successfully
scheduled.", percent completion is: "0"
<…>
- WARNING, JobStatus not completed, current status is: "Job in progress.",
percent completion is: "34"
<Output edited for brevity>
--- PASS, Final Detailed Job Status Results ---
JobState: Completed
Description: Job Instance
CompletionTime: 2018-05-31T11:10:31
PercentComplete: 100
StartTime: TIME_NOW
MessageId: PR19
Message: Job completed successfully.
EndTime: TIME_NA
Id: JID_277824009347
JobType: NICConfiguration
Name: ConfigNIC:NIC.Integrated.1-1-1
- JID_277824009347 job execution time: 0:10:26
6. Verify the new property settings to ensure that “InitiatorIPAddress” is set to 192.168.0.140:
C:\Python27>SetNetworkDevicePropertiesRedfish.py -ip 192.168.0.120 -u root -p
calvin -a NIC.Integrated.1-1-1
- Properties for network device NIC.Integrated.1-1-1 –
- iSCSIBoot Properties -
InitiatorDefaultGateway: 0.0.0.0
SecondaryTargetName:
CHAPUsername:
PrimaryLUN: 0
SecondaryVLANEnable: None
SecondaryVLANId: None
SecondaryDNS: 0.0.0.0
InitiatorNetmask: 0.0.0.0
IPMaskDNSViaDHCP: False
PrimaryTargetName:
PrimaryDNS: 0.0.0.0
PrimaryTargetTCPPort: 3260
SecondaryTargetTCPPort: 3260
IPAddressType: IPv4
TargetInfoViaDHCP: False
InitiatorName: iqn.1995-05.com.broadcom.iscsiboot
InitiatorIPAddress: 192.168.0.140
SecondaryTargetIPAddress: 0.0.0.0
SecondaryLUN: 0
CHAPSecret: