Release Notes

file:///T|/htdocs/SOFTWARE/smsbu/1_6/EN/readme/SBU_read.txt[10/23/2012 10:51:41 AM]
configuration has changed. Accepting these changes on the command
line may not be enough; enter the firmware utility and reset the
controller.
* On CERC ATA or CERC SATA RAID controller cards, disks that appear
in "Legacy" mode will not be available for RAID configuration in
Systems Build And Updates Utility. If you wish to use any disk that
is in "Legacy" mode as part of a RAID container, you need to use
the RAID controller firmware utility to initialize these disks. Likewise,
if all disks are in "Legacy" mode, then Systems Build And Updates Utility
may fail to configure RAID on the controller.
* The Server Setup program might fail if it runs when scrubbing is
active on a RAID virtual disk.
* Systems Build and Update Utility does not identify the boot device
when PERC 4DC controller is in cluster mode and the adapter's BIOS is
disabled. This will put Systems Build and Update Utility in an
infinite "Write Disk signature" and reboot loop. Use Systems Build
and Update Utility to install the operating system on PERC in a
non-cluster mode.
* Systems Build and Update Utility cannot detect the correct slot
number of PCI slots containing Adaptec RAID controllers. The message
"Unknown Slot Number" is displayed.
* On systems with low memory (less than 256 MB) and more than one
RAID controller, Systems Build and Update Utility may fail during
RAID configuration. Install the additional adapters after the
operating system has been installed on the first adapter.
* When using the Custom install script feature, commands which do
not return cause the system to stop responding during booting of Red
Hat Enterprise Linux or while registering components on Windows
installations.
* On DELL PERC/SAS RAID controller cards, disks that appear in "Foreign"
state will not be available for OS installation in non-RAID mode. If
all disks are in "Foreign" state, Systems Build and Update Utility
may fail to install OS on the controller in non-RAID mode.
* When you use Systems Build and Update Utility with a
keyboard-video-monitor (KVM) switch, the GUI may not display due to
incompatibility with the Server Interface PODs (SIPs) used. To view
the GUI, connect your monitor directly to your system or change the
SIP.
* To ensure the successful installation of an Operating System using
Server OS Installation, disable the DRAC/iDRAC Virtual Flash.
* When you are using the Server Operating System Installation module
in Systems Build and Update Utility to install an operating system,
the installation may fail if an external storage device is connected
to your system. Ensure that you disconnect the external storage