Owner's Manual

file:///T|/htdocs/SOFTWARE/smsbu/1_1/en/readme/readme.txt[10/23/2012 1:20:19 PM]
KNOWN ISSUES
######################################################################
The following subsections list the known issues with this release of
Systems Build and Update Utility.
* On Dell PowerEdge R610, T610, R710, M610, M710 systems with
internal USB, BIOS setting configuration for internal USB Port is
possible only if User Accessible/external (UA) USB ports are set to
"All Ports On". If UA USB ports are not set to "All Ports On"
and user tries to configure BIOS setting for internal USB Port
using Server Administrator GUI or CLI, the configuration will appear
to be successful but the changes will not take effect on next reboot. If
UA USB ports settings are changed from "All Ports On" to
"All Ports Off" or "Only Back Ports On", the USB will
be automatically set to "Off" during the next reboot.
======================================================================
KNOWN ISSUES ACROSS ALL OPERATING SYSTEMS
======================================================================
* Systems Build and Update Utility does not support RAID configuration
on any system with a SAS 5/iR or SAS 6/iR controller connected to
one hard drive.
To install Systems Build and Update Utility on a system with the
SAS 5/iR or SAS 6/iR controller, ensure atleast two hard drives are connected.
* Systems Build and Update Utility does not support RAID
Configuration on any system with a SATA 2s controller connected to
one hard drive. To install Systems Build and Update Utility on a
system with the SATA 2S controller, set the hard drive
configuration to "Native Mode" in the BIOS setup or configure RAID
using the "Ctrl+A" option.
* If a USB flash device is connected to the system, Systems Build and
Update Utility may fail to install the operating system. To resolve
the issue, perform one of the following actions:
- Remove the USB flash device.
- In the BIOS setup, under "Boot Order," move the "USB Device"
selection to the end of the list.
* The "View Hardware" feature in Systems Build and Update Utility
does not provide information on devices that are connected to
the chassis. The current listing of devices is not complete and
does not include devices such as Fibre Channel cards and Dell
Remote Access Controller 5 (DRAC 5).
* Use of localized special characters might cause the Systems Build
and Update Utility GUI to freeze intermittently.
* If there are multiple SAS or RAID controllers on the system,