file:///T|/htdocs/SOFTWARE/smsbu/1.0/en/readme/readme.txt[10/25/2012 1:33:14 PM]
and you try to configure the BIOS setting for the internal USB port
using SYSCFG, the configuration will appear to be successful
but the changes will not take effect after the next reboot. If
UA USB ports settings are changed from "All Ports On" to
"All Ports Off" or "Only Back Ports On," the USB port will
be automatically Set to "Off" during the next reboot.
======================================================================
KNOWN ISSUES ACROSS ALL OPERATING SYSTEMS
======================================================================
* Systems Build and Updates Utility does not support RAID
Configuration on any system with a SATA 2s controller connected to
one hard drive. To install Systems Build and Update Utility on a
system with the SATA 2S controller, set the hard drive
configuration to "Native Mode" in the BIOS setup or configure RAID
using the "Ctrl+A" option.
* If a USB flash device is connected to the system, Systems Build and
Update Utility may fail to install the operating system. To resolve
the issue, perform one of the following actions:
- Remove the USB flash device.
- In the BIOS setup, under "Boot Order," move the "USB Device"
selection to the end of the list.
* The "View Hardware" feature in Systems Build and Update Utility
does not provide information on devices that are connected to
the chassis. The current listing of devices is not complete and
does not include devices such as Fibre Channel cards and Dell
Remote Access Controller 5 (DRAC 5).
* On Power Edge 1800 systems, the "View Hardware" feature
in Systems Build And Updates Utility does not show the
CERC SATA 1.5/2S controller when it is set to Advanced
Technology Attachment (ATA) mode. This is due to the current
limitation of CERC SATA 1.5/2S; it has the same PCI device
ID for both ATA and RAID mode.
* Use of localized special characters might cause the Systems Build
and Update Utility GUI to freeze intermittently.
* If there are multiple SCSI or RAID controllers on the system,
Systems Build and Update Utility will always use the controller
listed first in the BIOS boot order list. If you want to use a
particular controller for the operating system, you must go to
the BIOS setup (F2 on boot) and set the given controller as the
first boot device.
* Systems Build and Update Utility does not support the configuration
of partitions or the installation of operating systems on systems
with PERC 2/SC, PERC 2/DC, or PERC 2/QC controllers or any
type of Fibre Channel storage adapter.