Release Notes

Table Of Contents
System Center Operations Manager adapter displays
a disconnected status
Description If the user account credentials are reset on the domain controller, the System Center Operations
Manager adapter displays a disconnected status with an unknown error.
Workaround Log in to SupportAssist Enterprise and provide valid System Center Operations Manager adapter
credentials.
Tracking Number SAE-10295
Device Overview pane does not display the operating
system version details
Description The Operating System attribute on the Device Overview pane does not display the operating system
version details for servers running Windows Server 2016 RS4 Core and Windows Server 2019 Core
operating systems.
Workaround None
Tracking Number SAE-14758
Unable to edit the adapter
Description
While editing the OpenManage Essential adapter, if incorrect credentials are entered, an Unable to edit
adapter message is displayed. However, the entered credentials are saved and the adapter displays a
Disconnected status.
Workaround Edit the adapter and enter the correct credentials. The adapter then displays a Connected status.
Tracking Number SAE-14660
Alerts not processed from Dell PowerVault MD Series
device
Description
Alerts are not processed:
When SupportAssist Enterprise installed on a Dell PowerVault MD Series device with more then one
RAID controller is upgraded to version 2.0.
If an alert is received from the other RAID controller that was not previously persisted by
SupportAssist Enterprise, immediately after the upgrade, and before inventory validation is complete.
Workaround None
Tracking Number SAE-12719
Service Tag of a chassis is displayed instead of the
Service Tag of a blade server
Description
In Blade servers with ESXI 6.5, the Service Tag of a chassis is displayed instead of the Service Tag of a
blade server, in the Host section of the collection report.
Known issues To be fixed in future releases 15