Release Notes
NOTE: For monitoring more than 100 devices in your environment, Dell recommends that you install SupportAssist
Enterprise on server that meets the specified hardware requirements. Periodic collections (required for ProSupport Plus
reporting) from more than 100 devices may result in a high processor or memory utilization on the monitoring server. This
high resource utilization may affect other applications that are running on the monitoring server, if the resources are shared
with other applications.
Network requirements
The following are the network requirements on the local system (the server where SupportAssist Enterprise is installed) and
remote devices.
● Internet connection — standard 1 GbE network.
● The local system must be able to communicate with the SupportAssist server hosted by Dell over HTTPS protocol.
● The local system must be able to connect to the following destinations:
○ https://apidp.dell.com — end point for the SupportAssist server.
○ https://is.us.dell.com/FUS/api/2.0/uploadfile — the file upload server where the collected system information is
uploaded.
○ https://is.us.dell.com/FUSCHUNK/api/1.0/file/uploadChunk — the file upload server where the collection files
greater than 10 MB in size are uploaded.
○ https://downloads.dell.com/ — for downloading Dell OpenManage Server Administrator (OMSA) and receiving new
SupportAssist Enterprise release information, policy files, and product support files.
The following table lists the ports that must be open on the local system.
Table 2. Network port requirements on the local system
Port Direction Usage
22 Out For adding the local system running a Linux operating system and for collecting system
information
25 Out For SMTP communication (required for SupportAssist Enterprise to send certain email
notifications through the SMTP server utilized by your company)
80 Out For HTTP communication
135 Out For Windows Management Instrumentation (WMI) communication
162 In For receiving alerts (SNMP traps) from remote devices
443 Out For Secure Socket Layer (SSL) communication, WS-Man communication, and verifying
SupportAssist Enterprise update information
1311 Out For Dell OpenManage Server Administrator (OMSA) communication
5700 In For opening SupportAssist Enterprise securely (HTTPS) from a remote system
5701, 5702, 5703,
and 5704
In For collecting system information from devices
9099 In For opening SupportAssist Enterprise (HTTP) from the local system
61616 In For processing SupportAssist Enterprise tasks
The following table lists the ports that must be open on remote devices that you want to monitor or collect system information
by using SupportAssist Enterprise.
Table 3. Network port requirements on remote devices
Device Type Port Usage
Server /
Hypervisor
22 For adding a remote device running a Linux operating system and to collect system
information
135 For adding a remote device running Windows (WMI) and to collect system information
161 For forwarding alerts (SNMP traps) to the local system
10