Table 60. Error code appendix (continued)
Error code Error message Possible resolution
Manually configuring the alert destination of iDRAC by
using the web interface on page 137.
5000_2 SNMP settings of the device could not be
configured because the integrated Dell Remote
Access Controller (iDRAC) does not have the
required license that is installed.
Ensure that iDRAC has an Enterprise or Express
license installed, and then try to configure the SNMP
settings through the Tasks > Configure SNMP
option.
5000_3 SNMP settings of the device could not be configured
because all configurable fields of the integrated Dell
Remote Access Controller (iDRAC) are occupied.
You must manually configure the SNMP settings of
the device. For instructions to manually configure the
SNMP settings, see Manually configuring the alert
destination of iDRAC by using the web interface on
page 137.
5000_4 SNMP settings of the device could not be configured
because the credentials you have entered do not
have the required privileges.
Ensure that the credentials have either Administrator
or Operator privileges on the integrated Dell Remote
Access Controller (iDRAC), and then try to configure
the SNMP settings through the Tasks > Configure
SNMP option on the device overview pane.
5000_5 SNMP settings of the device could not be configured
because an attempt to connect to the integrated Dell
Remote Access Controller (iDRAC) was unsuccessful.
Ensure that iDRAC is reachable from the system on
which SupportAssist Enterprise is installed, and then
try to configure the SNMP settings through the Tasks
> Configure SNMP option on the device overview
pane.
5000_6 SNMP settings of the device could not be configured
because the credentials you have entered are invalid.
Ensure that the credentials are valid, and then try
to configure the SNMP settings through the Tasks
> Configure SNMP option on the device overview
pane. If the problem persists, contact your system
administrator for assistance.
5000_7
5000_8
SNMP settings of the device could not be configured
because of an unexpected error.
You must manually configure the SNMP settings of
the device. For instructions to manually configure the
SNMP settings, see Manually configuring the alert
destination of iDRAC by using the web interface on
page 137.
5000_9 SNMP settings of the device could not be configured
because the user account does not have the
sufficient privileges on the device.
You must manually configure the SNMP settings of
the device. For instructions to manually configure the
SNMP settings, see Manually configuring the alert
destination of a server (Windows) on page 135 or
Manually configuring the alert destination of a server
(Linux) on page 137.
5000_10 SNMP settings of the device could not be configured
because the hostname/IP address of the system on
which SupportAssist Enterprise is installed was not
provided.
If you ran the script file to configure the SNMP
settings, ensure that you type the IP address of the
system on which SupportAssist Enterprise is installed
as an argument.
5000_11 SNMP settings of the device could not be configured
because the SNMP service is not installed on the
device.
Manually install the SNMP service on the device, and
then try to configure the SNMP settings through
the Tasks > Configure SNMP option on the device
overview pane.
5000_12 SNMP settings of the device could not be configured
because SupportAssist Enterprise does not support
the operating system running on the device.
For information on the operating systems supported
by SupportAssist Enterprise, see the SupportAssist
Enterprise Version 1.1 Support Matrix at https://
www.Dell.com/ServiceabilityTools.
5000_13 SNMP settings of the device could not be configured
because the SNMP service has not started.
Manually start the SNMP service on the device, and
then try to configure the SNMP settings through the
Tasks > Configure SNMP option.
Error code appendix 203