Install Guide
14 Best Practices for Sharing an iSCSI SAN Infrastructure with Dell PS Series and SC Series Storage using VMware vSphere
Hosts | 2015-A-BP-INF
4.2.2 Configuring the VMware iSCSI software initiator to access SC Series volumes
For SC Series storage, the discovery portal addresses must be added manually to the dynamic discovery tab
in the VMware iSCSI software initiator.
SC Series storage presents front-end target ports and each volume is presented as a unique LUN.
Redundant connections are made by creating multiple sessions with each of the virtual iSCSI target ports the
array.
For the purpose of this discussion, 10.10.10.35 and 10.10.10.36 are used as the SC Series iSCSI SAN
discovery addresses.
1. From the VMware ESXi Web GUI (local host management utility that has replaced the C# client),
select Storage, Adapters, and click Configure iSCSI.
2. In the Dynamic targets section, click Add dynamic target twice and enter the two SC Series iSCSI
target addresses and click Save configuration.