White Papers
BP1024 Scaling and Best Practices for Virtual Workload Environments with the FS7500 19
Figure 12 Increase in write throughput with increase in number of NICs and Virtual IP addresses
With more NICs, we saw an increase in throughput measured. We tested configurations from one NIC
up to eight NICs on the ESX host. In the figure above, the addition of more than four NICs does not
improve performance significantly since the backend disk configuration was saturated, so the
throughput is shown for only up to four NICs. Generally the throughput obtained scaled with the
number of physical NICs as long as sufficient backend disk resources are provided.
3.4.3 NAS service IP addresses used to connect to the datastore
Using the maximum number of NAS service virtual IP addresses enables better network throughput
from the FS7500 to fit with the IP based load balancing policy on the ESXi host vSwitch. The FS7500
can be accessed using multiple virtual NAS service IP addresses. These can be assigned through group
manager. Eight and 16 virtual IP addresses are available with use of one (two controllers) and two (four
controllers) FS7500s respectively.
0
50
100
150
200
250
300
350
400
450
1 2 3 4
Throughput MB/sec
Number of NICs used