White Papers

Configure the PowerVault ME4024 storage array
9 Deploying the 65TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2017 using
Dell EMC PowerEdge R640 and Dell EMC PowerVault ME4024 | 4023-CD-SQL
4 Configure the PowerVault ME4024 storage array
This section describes the configuration of the PowerVault ME4024 storage array. ME4 Series arrays can be
configured using the ME Storage Manager interface or ME4 Series command-line interface (CLI). This guide
covers the configuration steps using ME Storage Manager.
4.1 Configure local ports
On the Ports tab > System Settings, the Host Port Mode should be either FC or FC-and-iSCSI. When
using FC-and iSCSI, set Ports A0, A1, B0, and B1 to Speed: auto, Connection Mode: point-to-point.
4.2 Configure disks
Under Pools > Add Disk Group, add two disk groups. For each disk group, perform the following steps:
1. Specify a name (optional).
2. Select Virtual as the type (default).
3. Select A as the pool for the first disk group, and B as the pool for the second disk group (default)
4. For Data Protection, select RAID-5.
5. Select disks 0-11 for the first disk group, and disks 12-23 for the second disk group.
6. Click Add.
4.3 Create the host and volumes
A host object is used when presenting storage to a server. To create the host object, perform the following
steps:
1. Open ME Storage Manager.
2. Click the Hosts tab.
3. Click Action and select Host Setup. The Host Setup wizard appears.
4. In the Name box, enter the name of the server.
5. Select all four initiators listed. Verify that the initiator IDs match the FC ports on the host.
6. In the Host Bus Adapters list box, select all four FC ports for the server and click Next.
7. Select Do not group this host and click Next.