Install Guide
Configure VMware hosts to access SC Series arrays with SAS FE ports
25 Dell EMC SC Series Storage with SAS Front-end Support for VMware vSphere | 3027-CD-VM
3. The selected vSphere hosts are now listed below the server cluster object.
3.7 Create and map storage volumes to vSphere hosts
With cluster object created on the SC Series array, the next step is to create and map storage to the cluster
object. In this example, two volumes (150GB and 170GB) are created and mapped to the cluster object.
1. Right-click the desired Volumes folder and select Create Volume.
2. Provide an intuitive name for the volume, set the volume size, select a snapshot profile, and select
the data reduction profile. For Server, select the server cluster object. Configure the remaining
volume settings as desired, and click OK. In this example, the first volume created is SC-SAS-DS-01-
150GB.