White Papers

5 Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays | BP1008
2 Integration strategies
Before we begin describing integration strategies in detail, we first want to define the fully redundant iSCSI
SAN designs used as building blocks for integration and testing. Figure 1 shows a 1Gb redundant iSCSI SAN
design using a pair of stacked Dell Networking N or S Series 1Gb switches connecting to one or more
PS Series 1Gb storage arrays. Figure 2 shows a similarly designed 10Gb iSCSI SAN using a pair of stacked
Dell Networking N or S Series 10Gb switches connecting to one or more Dell Storage PS Series 10Gb
storage arrays.
Baseline design: 1Gb PS Series iSCSI SAN
Baseline design: 10Gb PS Series iSCSI SAN
The key differences between the 1Gb and 10Gb SAN designs shown in Figure 1 and Figure 2 are:
The PS Series 1Gb array is equipped with two 4-port 1Gb controllers.
The PS Series 10Gb array is equipped with two 2-port 10Gb controllers.