White Papers
44 Sizing and Best Practices for Online Transaction Processing Applications with Oracle 11g R2 using Dell PS Series | BP1003
A Configuration details
This section contains an overview of the configurations used for the testing described in this document.
Test configuration: hardware components
Solution configuration: hardware components
Description
Servers
2 x PowerEdge R720 servers:
Broadcom 5719 quad-port 1Gb NIC
Broadcom 57810 dual-port 10Gb
NIC
Two R720 servers as part of the Oracle
RAC configuration
4 x 1Gb NICs (B5719) trunked using
Linux kernel bonding used as RAC
interconnect
2 x 10Gb NICs used for iSCSI SAN
connectivity
Management server
1 PowerEdge R710 server:
Windows Server 2008
Management server for the entire
infrastructure
PS Series manager and SAN HQ
Network
2 x Dell EMC Networking S4810
switches:
Firmware: 9.1.0.0
2 x Dell EMC Networking S60
switches:
Firmware: 8.3.3.9
S4810: Two switches stacked together
for iSCSI SAN connectivity
S60: Two switches lagged together and
used for RAC interconnect
Storage
1 x PS6110XS storage array:
7 x 400GB SSDs, 17 x 600GB 10K
SAS drives
Firmware: 6.2.1
RAID 10
1 x PS6110E storage array:
24 x 2 TB SATA drives
Firmware: 6.2.1
RAID 50
PS6110XS: Backend storage for Oracle
database
PS6110E: Backend storage for Oracle
flashback recovery area and VM
repository