Setup Guide
LED Indicators
Front panel
• One dual-color LED indicator for system status
• One single-color LED indicator for power status
• Identication button with a single-color LED
Hard drive carrier
• One single-color activity LED
• One dual-color LED status indicator per drive
Storage controller
• Two single-color LEDs per Ethernet port indicating
activity and link speed
• One dual-color LED per SAS connector indicating
port activity and status
• One single-color LED indicating status
• One single-color LED indicating system faults
• One single-color LED for system identication
Power supply/cooling fan One dual-color LED handle indicating power supply and
cooling fan status
Power Supply Units (PSU)
AC power supply (per
power supply)
PSU Type 1 PSU Type 2 (Japan
Only)
PSU Type 3
Maximum output power 1485 W 1485 W 1378 W
Maximum input power 1688 W 1707 W 1584 W
Maximum input current 8.8 A 17.5 A 16 A
Maximum inrush current 55 A for 10 ms or
less
55 A for 10 ms or
less
55 A for 10 ms or
less
Nominal input voltage
operating range
200–240 VAC 100–240 VAC 100–240 VAC
Nominal input frequency 50/60 Hz 50/60 Hz 50/60 Hz
Thermal output/heat
dissipation
693 BTU per hour 757 BTU per hour 703 BTU per hour
14 Setting Up the Storage System