Deployment Guide

MPIO Configuration Instructions for Host Servers
If a Storage Manager wizard is used to configure host server access to the Storage Center, the Storage Manager attempts to
automatically configure MPIO with best practices.
NOTE: Compare the host server settings applied by the Storage Manager wizard against the latest Storage Center Best
Practices documents (listed in the following table) on the Dell TechCenter site (http://en.community.dell.com/
techcenter/storage/).
Table 1. MPIO Configuration Documents
Operating System Document with MPIO Instructions
Linux
Dell EMC SC Series with Red Hat Enterprise Linux (RHEL) 6x Best Practices
Dell EMC SC Series with Red Hat Enterprise Linux (RHEL) 7x Best Practices
Dell Storage SC Series Arrays with SUSE Linux Enterprise Server 12
VMware vSphere
Dell EMC SC Series Best Practices with VMware vSphere 5.x-6.x
Windows Server 2008 R2, 2012,
2012 R2, 2016
Dell Storage Center: Microsoft Multipath IO Best Practices
Connecting to Host Servers with Fibre Channel
HBAs
A storage system with Fibre Channel front-end ports connects to one or more FC switches, which connect to one or more host servers
with Fibre Channel HBAs.
Fibre Channel Zoning
When using Fibre Channel for front-end connectivity, zones must be established to ensure that storage is visible to the servers. Use the
zoning concepts discussed in this section to plan the front-end connectivity before starting to cable the storage system.
Dell recommends creating zones using a single initiator host port and multiple Storage Center ports.
WWN Zoning Guidelines
When WWN zoning is configured, a device may reside on any port, or change physical ports and still be visible, because the switch is
seeking a WWN.
List of guidelines for WWN zoning.
Include all Storage Center virtual World Wide Port Names (WWPNs) in a single zone.
Include all Storage Center physical World Wide Port Names (WWPNs) in a single zone.
For each host server HBA port, create a zone that includes the HBA port WWPN and multiple Storage Center virtual WWPNs on the
same switch.
For Fibre Channel replication from Storage Center system A to Storage Center system B:
Include all Storage Center physical WWPNs from system A and system B in a single zone.
Include all Storage Center physical WWPNs of system A and the virtual WWPNs of system B on the particular fabric.
Include all Storage Center physical WWPNs of system B and the virtual WWPNs of system A on the particular fabric.
NOTE:
Some ports may not be used or dedicated for replication, however ports that are used must be in these zones.
Fibre Channel Replication
Storage Center System A (Virtual Port Mode) to Storage Center System B (Virtual Port Mode)
Include all Storage Center physical WWPNs from system A and system B in a single zone.
Include all Storage Center physical WWPNs of system A and the virtual WWPNs of system B on the particular fabric.
Include all Storage Center physical WWPNs of system B and the virtual WWPNs of system A on the particular fabric.
34
Connect the Front-End Cabling