Deployment Guide

Figure 8. SCv300 and SCv320 Expansion Enclosure Drive Indicators
Item Control/Feature Indicator Code
1 Drive activity indicator
Blinking green – Drive has I/O activity
Steady green – Drive is detected and has no faults
2 Drive status indicator
Steady green – Normal operation
Blinking green – A command was sent to the drive to make the LED blink so that you can
identify the drive in the rack.
Blinking amber – Hardware or firmware fault
SCv3000 and SCv3020 Storage System Drive Numbering
The storage system holds up to 16 or 30 drives, which are numbered from left to right in rows starting from 0 at the top-left drive. Drive
numbers increment from left to right, and then top to bottom such that the first row of drives is numbered from 0 to 4 from left to right,
and the second row of drives is numbered from 5 to 9 from left to right.
Storage Manager identifies drives as XX-YY, where XX is the number of the unit ID of the storage system and YY is the drive position
inside the storage system.
Figure 9. SCv3000 Storage System Drive Numbering
Figure 10. SCv3020 Storage System Drive Numbering
18
About the SCv3000 and SCv3020 Storage System