Release Notes

Issue Description
SCOS-19269 In a two controller storage system, the active controller might reset during failover after performing a
Storage Center update on the peer controller.
SCOS-16677 When creating a Live Volume, choosing a destination volume that is mapped to a server might cause
the Live Volume to go offline. This might cause other volumes that use Deduplication or Compression
on the destination Storage Center to go offline.
SCOS-16377 In rare instances, a storage system with Live Volumes might reset when multiple changes are made to
the Fibre Channel switch configurations within a short time period.
Table 15. Fixed Replication and Live Volume Issues in Storage Center 7.1.1
Issue Description
SCOS-14576 Unable to perform Storage Center to PS Series group replication if the Storage Center volume name
contains Chinese, German, French, Japanese, or Spanish characters.
SCOS-14065 Thin Import setup is unable to activate the destination volume on a Storage Center when iSCSI is not
configured on the storage system.
SCOS-13152 A cross-platform replication snapshot from a PS Series array to a Storage Center might display the
wrong volume icon.
SCOS-1928 In ESXi 5.5 or later hosts, the status of a secondary Live Volume remains down after bringing the
primary Storage Center back online.
SCOS-706 Converting an existing ESXi datastore volume to Live Volume might cause the volume to disconnect
from the ESXi hosts.
Fixed Issues Related to Alerts and Reporting
The following issues are fixed in Storage Center 7.1:
Table 16. Fixed Alert and Reporting Issues in
Storage Center 7.1.30
Issue Description
SCOS-45091 The SNMP service might stop unexpectedly and require a restart.
Table 17. Fixed Alert and Reporting Issues in Storage Center 7.1.20
Issue Description
SCOS-29664 The storage system might report hundreds of Log Corrupt Page Address error messages during a
RAID restripe.
Table 18. Fixed Alert and Reporting Issues in Storage Center 7.1.12
Issue Description
SCOS-21331 The Storage Center email process might stop and fail to restart. This issue causes the Storage Center
alert email queue to fill up, which might cause a controller to reset.
Table 19. Fixed Alert and Reporting Issues in Storage Center 7.1.1
Issue Description
SCOS-12602 In rare instances, enabling SNMP causes the SNMP agent to stop unexpectedly and it cannot be
restarted.
SCOS-12287 Incorrect SSD endurance tracker alerts might appear if duplicate endurance tracker entries are
created.
SCOS-2906 For SCv2000 series storage systems, the Storage Center does not report if the SAS backend is
disconnected.
SCOS-2492 In Storage Center 6.6, enabling the AUTH LOGIN option in the SMTP Server settings might cause the
email manager to fail.
Dell Storage Center 7.1 Release Notes 15