Deployment Guide
• If a physical port or Ethernet switch becomes unavailable, the storage system is accessed from the switch in the other fault
domain.
• If a storage controller becomes unavailable, the virtual ports on the offline storage controller move to the physical ports on the
other storage controller.
NOTE: The Flex Port feature allows both Storage Center system management traffic and iSCSI traffic to use the same
physical network ports. However, for environments where the Storage Center system management ports are mixed with
network traffic from other devices (such as voice, backups, or other computing devices), separate iSCSI traffic from
management traffic using VLANs.
Steps
1. Connect each server and Ethernet switch 1 to the corporate/management network (shown in green).
2. Connect each server to both iSCSI networks.
3. Connect embedded fault domain 1 (shown in orange) to iSCSI network 1.
a. Connect the management port on storage controller 1 to Ethernet switch 1.
b. Connect the management port on storage controller 2 to Ethernet switch 1
4. Connect embedded fault domain 2 (shown in blue) to iSCSI network 2.
a. Connect the replication port on storage controller 1 to Ethernet switch 2.
b. Connect the replication port on storage controller 2 to Ethernet switch 2.
Figure 59. Two iSCSI Networks using the Embedded Ethernet Ports on Dual iSCSI Storage Controllers
1.
Corporate/management network 2. Server 1
3. Server 2 4. Ethernet switch 1 (fault domain 1)
5. Ethernet switch 2 (fault domain 2) 6. Storage system
7. Storage controller 1 8. Storage controller 2
5. To configure the fault domains and ports, click the Configure Embedded iSCSI Ports link on the Configuration Complete
page of the Discover and Configure Uninitialized SCv2000 Series Storage Centers wizard.
Next steps
Install or enable MPIO on the host servers.
NOTE: After the Storage Center configuration is complete, run the host access wizard to configure host server access
and apply MPIO best practices. For the latest best practices, see the Dell Storage Center Best Practices document on
the
Dell TechCenter site (http://en.community.dell.com/techcenter/storage/).