Deployment Guide
Item Control/Feature Icon Description
NOTE: To use the RELP port as a front-end connection to host servers,
a Flex Port license is required.
5 SAS activity indicators — There are four SAS PHYs per SAS port.
• Off: SAS PHY is not connected
• Steady green: SAS PHY is connected, but not active
• Blinking green: SAS PHY is not connected nor active
6 Storage controller status On: Storage controller completed POST
7 Recessed power off button Not currently used
8 Storage controller fault
• Off: No faults
• Steady amber: Firmware has detected an error
• Blinking amber: Storage controller is performing POST
9 Recessed reset button Not currently used
10 Identification LED
• Off: Identification disabled
• Blinking blue (for 15 sec.): Identification is enabled
• Blinking blue (continuously): Storage controller shut down to the Advanced
Configuration and Power Interface (ACPI) S5 state
11 USB port One USB 3.0 connector
12 Diagnostic LEDs (8) —
• Green LEDs 0–3: Low byte hex POST code
• Green LEDs 4–7: High byte hex POST code
13 Serial port (3.5 mm mini jack) Not for customer use
14 Two options:
• Four Fibre Channel ports
(Slot 1/Port 1, Slot 1/Port
2, Slot 1/Port 3, and Slot 1/
Port 4) with three LEDs
per port
• Two Fibre Channel ports
(Slot 1/Port 1 and Slot 1/
Port 2) with three LEDs
per port
— LEDs for the four 8 Gb Fibre Channel ports:
• All off: No power
• All on: Booting up
• Blinking amber: 2 Gbps activity
• Blinking green: 4 Gbps activity
• Blinking yellow: 8 Gbps activity
• Blinking amber and yellow: Beacon
• All blinking (simultaneous): Firmware initialized
• All blinking (alternating): Firmware fault
LEDs for the two 16 Gb Fibre Channel ports:
• All off: No power
• All on: Booting up
• Blinking amber: 4 Gbps activity
• Blinking green: 8 Gbps activity
• Blinking yellow: 16 Gbps activity
• Blinking amber and yellow: Beacon
• All blinking (simultaneous): Firmware initialized
• All blinking (alternating): Firmware fault
15 Mini-SAS port B (Slot 2/Port
2)
Back-end expansion port B
16 Mini-SAS port A (Slot 2/Port
1)
Back-end expansion port A
About the SCv2000/SCv2020 Storage System
17