Deployment Guide
SCv2000/SCv2020 Storage System Back-Panel Features and Indicators
The back panel of the SCv2000/SCv2020 contains the storage controller indicators and power supply indicators.
Figure 7. SCv2000/SCv2020 Storage System Back-Panel View
Item Name Icon Description
1 Power supply/cooling
fan module (PSU) (2)
— Contains a 580 W power supply and fans that provide cooling for the storage
system.
2 Battery backup unit
(BBU) (2)
— Allows the storage controller to shut down smoothly when a loss of AC power
is detected.
3 Storage controller (1 or
2)
— Each storage controller contains:
• Back-end ports: Two 6 Gbps SAS ports
• Front-end ports: Fibre Channel ports, iSCSI ports, or SAS ports
• MGMT port: Embedded Ethernet/iSCSI port that is typically used for
system management
NOTE: The MGMT port can share iSCSI traffic if the Flex Port
license is installed.
• REPL port: Embedded iSCSI port that is typically used for replication to
another Storage Center
4 Cooling fan fault
indicator (2)
• Off: Normal operation
• Steady amber: Fan fault or the storage system is having a problem
communicating with the PSU
• Blinking amber: PSU is in programming mode
5 AC power fault indicator
(2)
• Off: Normal operation
• Steady Amber: PSU has been removed or the storage system is having a
problem communicating with the PSU
• Blinking amber: PSU is in programming mode
6 AC power status
indicator (2)
• Off: AC power is off, the power is on but the PSU is not in the storage
system, or a hardware fault is possible
• Steady green: AC power is on
• Blinking green: AC power is on and the PSU is in standby mode
7 DC power fault indicator
(2)
• Off: Normal operation
• Steady amber: PSU has been removed, a DC or other hardware fault has
occurred, or the storage system is having a problem communicating with
the PSU
About the SCv2000/SCv2020 Storage System