Administrator Guide

Replace a Failed Power Supply
This step-by-step wizard guides you through replacing a failed power supply in an enclosure in the Storage Center.
Prerequisite
This wizard is only available for the SCv2000 series, and can be completed without a controller outage.
Steps
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, expand Enclosures, then select and expand the enclosure with the failed power supply.
The Enclosure view is displayed.
4 Under the selected enclosure, click Power Supplies.
The Power Supplies view is displayed.
5 In the right pane, select the failed power supply, then click Replace Power Supply.
The Replace Failed Power Supply wizard opens.
6 Refer to the graphic in the wizard to locate the failed power supply. Click Next.
7 Follow the instructions to remove the failed power supply. Click Next.
8 Follow the instructions to insert the replacement power supply. Click Next to verify the replacement.
If this verication fails, an error message is displayed. You can proceed to the next step once the error is corrected and validated.
9 Click Finish to exit the wizard.
Clear the Under Voltage Status for a Power Supply
Clear the under voltage status for an enclosure power supply to acknowledge that you are aware of it.
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, expand Enclosures, then select and expand an enclosure.
The Enclosure view is displayed.
4 Under the selected enclosure, click Power Supplies.
The Power Supplies view is displayed.
5 In the right pane, select the power supply, then click Request DC Undervoltage Clear.
Clear the Swap Status for a Temperature Sensor
The swap status for a temperature sensor is set when the component that contains the sensor is replaced.
1 If the Storage Manager Client is connected to a Data Collector, select a Storage Center from the Storage view.
2 Click the Hardware tab.
3 In the Hardware tab navigation pane, expand Enclosures, then select and expand an enclosure.
The Enclosure view is displayed.
4 Under the selected enclosure, click Temperature Sensor.
The Temperature Sensor view is displayed.
5 In the right pane, select the temperature sensor, then click Request Swap Clear.
302