Release Notes
Storage Center Operating System Guidelines
The following scalability guidelines are the maximum recommended design guidelines for Storage Center
controller SCv2000 series running Storage Center 6.6.
Storage Center Object Supported Maximum
Disk Folder
• 4 disk folders
Server
• 100 servers (Total number of servers includes physical servers, virtual
servers, and server clusters.)
• 100 server folders
• 200 server HBA initiator ports (Total number of HBA initiator ports
includes all physical and virtual ports that are visible to the SAN.)
Volume
• 500TB maximum volume size (or the maximum addressable storage
space, whichever is less)
• 1000 volumes
• 500 volume folders
Replay
• 2000 Replays
• 1000 Replay profiles
• 100 Replay history profiles
• 25 volumes per consistency group
Replication
• 125 source replications
• 500 target replications
The following scalability guidelines are the maximum recommended design guidelines for Storage Center
controllers SC8000, SC4020, and CT-SC040 in a Storage Center running Storage Center 6.6.
Storage Center Object Supported Maximum
Disk Folder
• 10 disk folders
Server
• 500 servers (Total number of servers includes physical servers, virtual
servers, and server clusters.)
• 500 server folders
• 1000 server HBA initiator ports (Total number of HBA initiator ports
includes all physical and virtual ports that are visible to the SAN.)
Volume
• 500TB maximum volume size (or the maximum addressable storage
space, whichever is less)
• 2000 volumes
• 500 volume folders
Replay
• 16,000 Replays (4000 Replays for an SC4020)
• 1000 Replay profiles
• 100 Replay history profiles
• 40 volumes per consistency group
Replication
• 500 source replications (SC4020: 256 replications)
Dell Storage Center 6.6 Release Notes
3