Back-Panel Connectors (per EMM)
SAS connectors SAS A and B connectors for connecting an expansion enclosure to a storage
system.
NOTE: SAS connectors are SFF-8086/SFF-8088 compliant
Serial connector One 6-pin UART mini-DIN connector
NOTE: Not for customer use.
LED Indicators
Front panel
One two-color LED indicator for system status
One single-color LED indicators for power status
Hard-drive carrier
One single-color activity LED
One two-color LED status indicator per drive
EMM Three two-color LED status indicators, one each for the two EMM SAS ports
and one for the EMM status
Power supply/cooling
fan
Three LED status indicators for power supply status, power supply/cooling
fan fault status, and AC status
Power Supplies
AC power supply (per power supply)
Wattage 700 W
Voltage 100–240 VAC
Frequency 50/60 Hz
Amperage 8.6 A at 100 V, 4.3 A at 250 V
Heat dissipation SC100: 2,389 BTU/hr (at 700W) 1,536 BTU/hr Max
SC120: 2,389 BTU/hr (at 700W) 1,621 BTU/hr Max
Maximum inrush current Under typical line conditions and over the entire system ambient operating
range, the inrush current may reach 55 A per power supply for 10 ms or less
Available Hard Drive Power (per Slot)
Supported hard drive
power consumption
(continuous)
SC100: Up to 1.16 A at +5 V, up to 1.6 A at +12 V
SC120: Up to 1.2 A at +5 V, up to 0.5 A at +12 V
EMM Power (per Slot)
Maximum power
consumed by EMM
SC100: 11 W at +12 V
SC100/SC120 Expansion Enclosure Technical Specifications