Post-Replacement Procedures
Perform the procedures described in this section after replacing a component of an SC100/SC120
expansion enclosure.
Starting Up the Storage System and Expansion Enclosures
If the storage system and expansion enclosures were previously shut down, perform this procedure to
start them up.
1. Plug the power cables into the power supply/cooling fan modules of the storage system and
expansion enclosures.
2. Turn on each expansion enclosure by pressing the power switches on the power supply/cooling fan
modules.
NOTE: Always turn on the expansion enclosures before turning on the storage systems.
3. Turn on the storage system by pressing the power switches on the power supply/cooling fan
modules.
4. Use the Dell Storage Client to make sure the replacement part is recognized and shown as up and
running.
Send Diagnostic Data Using Dell SupportAssist
Use Dell SupportAssist to send diagnostic data to Dell Technical Support.
1. Use the Storage Client to connect to the Storage Center.
2. In the Summary tab, click Send SupportAssist Information Now, which is located under
SupportAssist Actions in the Status pane. The Send SupportAssist Information Now dialog box
opens.
3. Select Storage Center Configuration and Detailed Logs.
4. Click OK.
The Storage Client displays the status of the SupportAssist action. A second dialog box opens when
the transfer of SupportAssist information has completed successfully.
5. Click OK.
6. (Optional) If the Storage Center is in maintenance mode, return it to normal operation.
Replacing SC100/SC120 Expansion Enclosure Components
27