Users Guide

Storage Solutions Guide 25
NOTE: Follow the steps for Windows Server 2008 within the documentation.
The configuration and software installation detailed in the guide should be
carried out in the parent partition.
Best practices during configuration:
For information on appropriately sizing the LUNs, see "Sizing Storage
for Your VM" on page 30.
LUNs that store virtual machine data should reside on a fault tolerant
RAID group.
Each virtual machine should have its own unique set of LUNs that
contain the virtual machine files and virtual machine hard drives.
3
Provide virtual machines with the provisioned storage as either
passthrough disks or format the disks and place VHDs on the formatted
partition (see "Appendix B: Preparing Storage for Your VMs" on page 40).
Fibre Channel Arrays
Dell|EMC CLARiiON Arrays
The Dell|EMC CLARiiON series of arrays provides high performance,
availability, and advanced management features. In addition, the latest
generation CX3 and CX4 series supports both iSCSI and FC connectivity on
one array.