Users Guide

Storage Solutions Guide 23
c
In the right pane of the
Registry Editor
window, verify that the key
value is set to 0x000000a0 (160).
d
Close the
Registry Editor
window and reboot the VM.
For VMs running a Linux operating system with the 2.6 kernel, perform
the following steps:
a
Create a new udev rule by creating a file with the name
96-dell-
sto.rules
at /etc/udev/rules.d/.
b
Type the following text (case sensitive) within the file and save the
file:
KERNEL=="sd*[!0-9]", ACTION=="add", RUN+=
"/bin/sh -c 'echo 200 >
/sys$DEVPATH/device/timeout'"
c
Reboot the VM.
Dell|EMC CLARiiON Arrays
The Dell|EMC CLARiiON™ series of arrays provides high performance,
availability, and advanced management features. In addition, the latest
generation CX3 and CX4 series supports both iSCSI and FC connectivity on
one array. The number of hosts supported varies with by model, refer to the
product documentation available on powerlink.emc.com for more
information.