Deployment Guide

Version Description
9.9(0.0) Introduced on the C9010.
Usage Information
The recover-timer configuration sets the time interval for OF-instance to receive all configured flows from
the controller after the reconnect timer expires or when it is canceled
.
Related Commands
recover-timer
Set a time interval for OF-instance to receive all configured flows from the controller when the reconnect-timer expires or is canceled.
Syntax
recover-timer seconds
To return to the default value, use the no recover-timer command.
Parameter
seconds Enter the recover-timer in seconds. The range is from 10 to 1800 seconds.
Defaults 30 seconds.
Command Modes OPEN-FLOW
Command History
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
Usage Information
The recover-timer is enabled when the reconnect-timer is canceled or when the switch is able to re-
establish a connection with the controller. Therecover-timer sets a limit on the time that the controller may
take to download all flows to the switch (after RPM switch-over) without impacting the traffic flow.
Related Commands reconnect-timer — Set a time interval for OF-instance to reconnect with the controller before declaring the
controller as unreachable.
show openflow
Display general information about OpenFlow instances.
Syntax
show openflow [of-instance[of-id]]
Parameter
of-instance of-id (OPTIONAL)
Enter the keywords of-instance to display information such as administrative state,
interface-type, and operational state for all OpenFlow instances.
(OPTIONAL) Enter the keywords of-instance followed by the OF instance ID to
display details for the specified OF instance. The range is from 1 to 8.
Defaults None
Command Modes EXEC
OpenFlow Commands 55