Deployment Guide
Platform ACL Mode Maximum Scale Number Tested
S6100–ON FP Region set to 9 with Interface type set as “Port” Max Flow Entries: 744
FP Region set to 9 with Interface type set as
“Any /Vlan”
Max Flow Entries: 372
S4048–ON FP Region set to 8 with Interface type set as
“Port”
Max Flow Entries: 1000
FP Region set to 8 with Interface type set as
“Any /Vlan”
Max Flow Entries: 500
S3048-ON FP Region set to 8 with Interface type set as
“Port”
Max Flow Entries: 1000
FP Region set to 8 with Interface type set as
“Any /Vlan”
Max Flow Entries: 500
S4048T-ON (Open Day Light Controller for OF
1.3)
FP Region set to 8 with Interface type set as
“Port”
Max Flow Entries: 2150
FP Region set to 8 with Interface type set as
“Any /Vlan”
Max Flow Entries: 1075
S4048T-ON (Big Switch Controller for OF 1.0) FP Region set to 8 with Interface type set as
“Port”
Max Flow Entries: 2000
FP Region set to 8 with Interface type set as
“Any /Vlan”
Max Flow Entries: 1000
S6010-ON FP Region set to 8 with Interface type set as
“Port”
Max Flow Entries: 2000
FP Region set to 8 with Interface type set as
“Any /Vlan”
Max Flow Entries: 1000
FDB Mode
Table 8. — Max OF Scaling Numbers in FDB Mode
Platform NPU FDB Scale Number Tested Software Limit
S4820T Trident + 128,000 128,000
S4820T Trident + 128,000 128,000
S6000 Trident 2 130,000 160,000
Z9100–ON Tomahawk 130,000 136,000
S4048–ON Trident 2 130,000 160,000
S6010-ON Trident 2+ 132,000 160,000
S4048T-ON Trident 2+ 132,000 160,000
S3048–ON Helix 58,000 64,000