Deployment Guide

Related
Commands
show openflow — Displays general information about OpenFlow instances.
shutdown (OpenFlow Instance)
Enable or disable the OpenFlow instance.
Z9000 S4810 S4820T
Syntax
[no] shutdown
Defaults Disabled (shutdown)
Command Modes OPENFLOW INSTANCE
Command History
Version 9.2(0.0) Introduced on the S4820T and MXL Switch.
Version 9.1(0.0) Introduced on the S4810 and Z9000.
Usage
Information
To enable the OpenFlow instance, use the no shutdown command. When you use the no
shutdown command, the OpenFlow instance sends a request to the OpenFlow controller to
establish a connection.
To disable an OpenFlow instance, use the shutdown command. Use the shutdown
command before making any configuration changes to the OpenFlow instance.
All OpenFlow instances are disabled by default.
Related
Commands
openflow of-instance — Creates or modifies an OpenFlow instance.
controller — Configures the controller used by OpenFlow.
38