Deployment Guide
• To establish a connection with the controller, enable the OF instance using the no
shutdown command.
• To modify the OF instance, disable the OF instance first using the shutdown
command.
• You can configure one controller IP and one TCP port for each OF instance.
• The number of supported flows depends on the flow type. The following table provides
the number of supported flows for each flow type:
Flow Type Maximum Number of Available Flows
ACL 256 or 512 (depending on ACL CAM carving)
L2 48,000
LB 24,000
L3 6,000
• To avoid session timeout issues if you change the time or date on the system clock,
you must disable and re-enable all existing OpenFlow instances.
Related
Commands
shutdown — Enables or disables the OpenFlow instance.
show openflow — Displays general information about OpenFlow instances.
controller — Specifies the OpenFlow controller configuration that the OpenFlow instance uses
to establish a connection.
show openflow
Display general information about OpenFlow instances.
Z9000 S4810 S4820T
Syntax
show openflow [of-instance[of-id]]
Parameter
of-instance
of-id
(OPTIONAL)
Enter the keywords of-instance to display information such as
administrative state, interface-type, and operational state for all
OpenFlow instances.
(OPTIONAL) Enter the keywords of-instance followed by the OF
instance ID to display details for the specified OF instance. The range
is from 1 to 8.
Defaults None
Command Modes EXEC
Command History
Version 9.2(0.0) Introduced on the S4820T and MXL Switch.
Version 9.1(0.0) Introduced on the Z9000 and S4810.
Example
FTOS#show openflow of-instance 1
Instance : 1
Admin State : Down
Interface Type : Port