Deployment Guide

To establish a connection with the controller, enable the OF instance using the no
shutdown command.
To modify the OF instance, disable the OF instance first using the shutdown
command.
You can configure one controller IP and one TCP port for each OF instance.
The number of supported flows depends on the flow type. The following table provides
the number of supported flows for each flow type:
Flow Type Maximum Number of Available Flows
ACL 256 or 512 (depending on ACL CAM carving)
L2 48,000
LB 24,000
L3 6,000
To avoid session timeout issues if you change the time or date on the system clock,
you must disable and re-enable all existing OpenFlow instances.
Related
Commands
shutdown — Enables or disables the OpenFlow instance.
show openflow — Displays general information about OpenFlow instances.
controller — Specifies the OpenFlow controller configuration that the OpenFlow instance uses
to establish a connection.
show openflow
Display general information about OpenFlow instances.
Z9000 S4810 S4820T
Syntax
show openflow [of-instance[of-id]]
Parameter
of-instance
of-id
(OPTIONAL)
Enter the keywords of-instance to display information such as
administrative state, interface-type, and operational state for all
OpenFlow instances.
(OPTIONAL) Enter the keywords of-instance followed by the OF
instance ID to display details for the specified OF instance. The range
is from 1 to 8.
Defaults None
Command Modes EXEC
Command History
Version 9.2(0.0) Introduced on the S4820T and MXL Switch.
Version 9.1(0.0) Introduced on the Z9000 and S4810.
Example
FTOS#show openflow of-instance 1
Instance : 1
Admin State : Down
Interface Type : Port
36