Deployment Guide

controller
Specify the OpenFlow controller configuration that the OpenFlow instance uses to establish a connection.
Z9000 S4810 S4820T
Syntax controller {controller-id}{ip-address}[port port-number]tcp
Parameter
controller-id
Enter the controller number (must be 1).
ip-address
Enter the IP address of the controller.
port
port-number
Enter the keyword port followed by the port number to use for the
connection. The range is from 1 to 65535.
Defaults Default port number for the TCP connection is 6633.
Command Modes OPENFLOW INSTANCE
Command History
Version 9.2(0.0) Introduced on the S4820T and MXL switch.
Version 9.1(0.0) Introduced on the Z9000 and S4810.
Usage
Information
The controller number must be entered as 1 to enable OpenFlow. Only TCP connection is
supported.
Related
Commands
openflow of-instance — Creates or modifies an OpenFlow instance.
debug openflow packets
Enable debugging for OpenFlow packets.
Z9000 S4810 S4820T
Syntax
debug openflow packets packet-type {packets} of-instance {of-
id}
Parameter
{packet-type
packet-type
}
Enter the keywords packet-type followed by one of the following
packet types:
all
Enable debugging for all packets.
barrier-
reply
Enable debugging for barrier-reply packets.
barrier-
request
Enable debugging for barrier-request
packets.
echo-reply
Enable debugging for echo-reply packets.
echo-request
Enable debugging for echo-request packets.
30