Users Guide

Table Of Contents
CONFIGURATION
使
使 notification-type notification-option
notification-type notification-option
SNMP 使
SNMP 使 snmp-server host
10.4.1.0 MX9116n MX5108n 10.5.0.1
SmartFabric
no SNMP
OS10(config)# snmp-server enable traps envmon fan
OS10(config)# snmp-server enable traps envmon power-supply
OS10(config)# snmp-server enable traps snmp
OS10(config)# no snmp-server enable traps snmp
10.4.1.0 or later
snmp-server engineID
SNMP ID
snmp-server engineID [local engineID] [remote ip-address {[udp-port port-
number] remote-engineID}]
local engineID SNMP ID
27
remote ip-address 访 SNMP SNMP IPv4 IPv6
udp-port port-number UDP 0 65535
remote-engineID SNMP ID0x
ID 使 MAC
CONFIGURATION
使
ID SNMP
SNMP ID
使 SNMP
ID
ID使 show snmp engineID local
10.4.2.0 MX9116n MX5108n 10.5.0.1
SmartFabric
no ID
OS10(config)# snmp-server engineID local 80:00:02:b8:04:61:62:63
OS10(config)# snmp-server engineID local 80:00:02:b8:04:61:62:63
% Warning: Localized passwords need to be regenerated for local user.
OS10(config)# snmp-server engineID remote 1.1.1.1 0xaaffcc
OS10(config)# snmp-server engineID remote 1.1.1.2 udp-port 432 0xabeecc
10.4.2.0 or later