Users Guide

Table Of Contents
Sequence Number: 1
Severity: critical
Type: 1081367
Source: Node.1-Unit.1
Name: EQM_THERMAL_CRIT_CROSSED
Description:
Raise-time: Sat 10-06-2018 0:1:5
Ack-time: Sun 10-07-2018 20:39:47
New: true
State: raised
NOS# show alarms severity minor
Active-alarm details - 1
-------------------------------------------
Sequence Number: 4
Severity: minor
Type: 1081375
Source: /psu/1
Name: EQM_MORE_PSU_FAULT
Description: psu 2 is not working correctly
Raise-time: Sun 10-07-2018 18:39:47
Ack-time: Sun 10-07-2018 20:39:47
New: true
State: acknowledged
-------------------------------------------
10.4.3
show alarms summary
show alarms summary
EXEC
使
OS10# show alarms summary
Active-alarm Summary
-------------------------------------------
Total-count: 2
Critical-count: 0
Major-count: 1
Minor-count: 1
Warning-count: 0
-------------------------------------------
10.2.0E or later
show event history
show event history [summary] [reverse] [severity severity-name] [details]
[sequence sequence-number]
summary
reverse
severity
details
OS10 1297