Users Guide

Table Of Contents
Hardware Revision : X01
Software Version : 10.3.2E(X)
Physical Ports : 48x25GbE, 6x100GbE
BIOS : 3.36.0.1-2
SMF : 0.1
CPLD1 : 1.0
CPLD2 : 1.0
CPLD3 : 1.0
CPLD4 : 1.0
-- Power Supplies --
PSU-ID Status Type AirFlow Fan Speed(rpm) Status
----------------------------------------------------------------
1 fail
2 up AC NORMAL 1 9056 up
-- Fan Status --
FanTray Status AirFlow Fan Speed(rpm) Status
----------------------------------------------------------------
1 up NORMAL 1 8348 up
2 8585 up
2 up NORMAL 1 8278 up
2 8718 up
3 up NORMAL 1 8420 up
2 8529 up
4 up NORMAL 1 8348 up
2 8680 up
Diagnostic commands
location-led interface
Changes the location LED of the interface.
Syntax
location-led interface ethernet {chassis/slot/port[:subport]} {on | off}
Parameters
chassis/slot/port[:subport] — Enter the ethernet interface number.
on | off — Set the interface LED to be on or o.
Default Not congured
Command Mode EXEC
Usage Information Use the location-led interface command to change the location LED for the specied interface.
Example
OS10# location-led interface ethernet 1/1/1 on
OS10# location-led interface ethernet 1/1/1 off
Supported Releases 10.3.0E or later
546 Troubleshoot OS10