Table 19. FCOE system log messages (continued)
System log message Severity Description Recommended action
%FCOE_CONFLICT_VLAN: FIP
Snooping conflict in FCF
advertised VLAN. FIP snooping
not enabled for this VLAN
Critical FCOE VLAN is different from the FCF
advertised VLAN.
Configure same FCOE VLAN
on all the switches, that is,
FSB or NPG and F-port.
%FCOE_SESSION_UPDATE:
FCoE Session
Informational This log is displayed when a new FCOE
session is created or an existing FCOE
sesssion is cleared.
Just an Information to the
user.
%FCOE_ENODE_TIMEOUT:
FCoE ENode Timeout
Critical This log is displayed where there is no
enode keeplive for 5 * FKA advertised by
the FCF.
Check the FCOE client. Try
shut or no shut of the enode
port. Check VLAN request
response is sent.
%FCOE_FCF_TIMEOUT: FCoE
FCF Timeout
Critical This log is displayed when there is no FCF
advertisement for 5 * FKA_ADV_PERIOD.
Do shut or no shut of FCF
facing port. Check FCOE
statistics to verify Multicast
FCF advertisement counter
is incremented.
%FCOE_SESSION_TIMEOUT:
FCoE Session Timeout
Critical This log is displayed when there is no VN
keep alive received from a fcoe client for 5
* FKA_VN_PERIOD (90) seconds.
After the session time out,
the C N A will try to
re-establish the session by
sending vlan request. If not
try shut/no shut of enode
port.
%FCOE_ENODE_SESSION_LIMI
T_CHANGE: One or more ENode
MACs have more sessions than
the newly configured limit. The
new limit will be applied to future
sessions
Informational This log is displayed when we change the
value of fcoe max-sessions-per-enodemac.
For example their exist 32 sessions and
we limit it by setting the value to 10.
Existing session will not be affected by this
configuration change. But the new session
request will be dropped.
Information to the user on
configuration change.
%FCOE_APP_TLV:
FCOE_APP_TLV
Informational This log is displayed when FCOE
application TLV is configured.
No action required.