Users Guide

Table Of Contents
Table 15. EQM system log messages (continued)
System log message Severity Description Recommended action
%EQM_MEDIA_VOLTAGE_LOW
_WARNING: Media low warning
voltage threshold crossed minor
warning
Warning Digital Optical Monitoring detects that
the low voltage minor threshold is
crossed.
Check whether the media is
supported. Try replacing the
media.
%EQM_MEDIA_VOLTAGE_LOW:
Media low voltage threshold
crossed major warning
Critical Digital Optical Monitoring detects that
the low voltage major threshold is
crossed.
Check whether the media is
supported. Try replacing the
media.
%EQM_MEDIA_RX_POWER_HI
GH: Media high rx_power
threshold crossed major warning
Critical Digital Optical Monitoring detects that
the high rx power major threshold is
crossed.
Check whether the media is
supported. Try replacing the
media.
%EQM_MEDIA_RX_POWER_HI
GH_WARNING: Media high
warning rx_power threshold
crossed minor warning
Warning Digital Optical Monitoring detects that
the high rx power minor threshold is
crossed.
Check whether the media is
supported. Try replacing the
media.
%EQM_MEDIA_RX_POWER_LO
W_WARNING: Media low warning
rx_power threshold crossed
minor warning
Warning Digital Optical Monitoring detects that
the low rx power minor threshold is
crossed.
Check whether the media is
supported. Try replacing the
media.
%EQM_MEDIA_RX_POWER_LO
W: Media low rx_power threshold
crossed major warning
Critical Digital Optical Monitoring detects that
the low rx power major threshold is
crossed.
Check whether media is
supported. Try replacing the
media.
%EQM_MEDIA_TX_POWER_HI
GH: Media high tx_power
threshold crossed major warning
Critical Digital Optical Monitoring detects that
the high tx power major threshold is
crossed.
Check whether the media is
supported. Try replacing the
media.
%EQM_MEDIA_TX_POWER_HI
GH_WARNING: Media high
warning tx_power threshold
crossed minor warning
Warning Digital Optical Monitoring detects that
the high tx power minor threshold is
crossed.
Check whether the media is
supported. Try replacing the
media.
%EQM_MEDIA_TX_POWER_LO
W_WARNING: Media low warning
tx_power threshold crossed
minor warning
Warning Digital Optical Monitoring detects that
the low tx power minor threshold is
crossed.
Check whether the media is
supported. Try replacing the
media.
%EQM_MEDIA_TX_POWER_LO
W: Media low tx_power threshold
crossed major warning
Critical Digital Optical Monitoring detects that
the low tx power major threshold is
crossed.
Check whether the media is
supported. Try replacing the
media.
%EQM_MEDIA_BIAS_HIGH:
Media high bias threshold crossed
major warning
Critical Digital Optical Monitoring detects that
the high bias current major threshold is
crossed.
Check whether the media is
supported. Try replacing the
media.
%EQM_MEDIA_BIAS_HIGH_WA
RNING: Media high warning bias
threshold crossed minor warning
Warning Digital Optical Monitoring detects that
the high bias current minor threshold is
crossed.
Check whether the media is
supported. Try replacing the
media.
%EQM_MEDIA_BIAS_LOW_WA
RNING: Media low warning bias
threshold crossed minor warning
Warning Digital Optical Monitoring detects that
the low bias current minor threshold is
crossed.
Check whether media is
supported. Try replacing the
media.
%EQM_MEDIA_BIAS_LOW:
Media low bias threshold crossed
major warning
Critical Digital Optical Monitoring detects that
the low bias current major threshold is
crossed.
Check whether media is
supported. Try replacing the
media.
EQM system log message reference 35