Users Guide
Table Of Contents
- Dell EMC SmartFabric OS10 System Log Message Reference Guide Release 10.5.2
- Contents
- Revision history
- About this guide
- System log messages overview
- ACL system log message reference
- AFS system log message reference
- ALM_ACCNT_MAC system log message reference
- ALM_CLOCK system log message reference
- BFD system log message reference
- BGP system log message reference
- CMS system log message reference
- Configuring LLFC system log message reference
- DCBX system log messages
- DENIED_ARP system log message reference
- DOT1X system log message reference
- DYNAMIC_MGMT system log message reference
- EQM system log message reference
- ETL system log message reference
- EVPN system log message reference
- FC_SVCS system log message reference
- FCOE system log message reference
- FEFD system log message reference
- IGMP system log message reference
- IP system log message reference
- IPv6 system log message reference
- ISCSI system log message reference
- LACP system log message reference
- LADF system log message reference
- LB system log message reference
- LLDP system log message reference
- MGMT_CLISH system log message reference
- SYSTEM_MODE_CHANGE system log message reference
- MLD system log message reference
- NDM system log message reference
- PBR match access-list system log message reference
- OPEN_FLOW system log message reference
- OSPFv2 system log message reference
- OSPFv3 system log message reference
- PIM system log message reference
- PTP system log message reference
- QoS system log message reference
- RAGUARD_EVENT system log message reference
- RAGUARD system log message reference
- Routemap with match ACL system log message reference
- Scale VLAN profile system log message reference
- Static and dynamic route system log message reference
- SA system log message reference
- STATIC_MGMTsystem log message reference
- STP system log message reference
- UFD system log message reference
- USER_ROLE_CHANGED system log message reference
- Delay restore port system log message reference
- VLT system log message reference
- VRF system log message reference
- VXLAN system log message reference
- IFM system log message reference
- Index
Table 15. EQM system log messages (continued)
System log message Severity Description Recommended action
%EQM_MEDIA_NOT_PRESENT:
Media removed
Critical A media(port) is removed. If not expected, check
whether the media is
properly inserted.
%EQM_MEDIA_QSA28_EXPECT
ED: QSA28 adapter expected
Critical The platform expects a QSA28 adapter,
but the inserted optics is not QSA28.
Check the media adapter
connected to the port. If
the media adapter is a
QSA adapter, then replace
the adapter with a QSA28
adapter.
%EQM_VERSION_MISMATCH:
Unit down reason: version
mismatch
Informational Unit went down due to version mismatch. No action required.
%EQM_TYPE_MISMATCH: Unit
down reason: type mismatch
Informational Unit went down due to equipment type
mismatch.
No action required.
%EQM_ADMIN_DOWN: Unit
down reason: admin down
Informational Unit went down due to admin state
down.
No action required.
%EQM_UNLICENSED: Unit down
reason: unlicensed
Informational Unit went down due to unlicensed reason. No action required.
%EQM_SOFTWARE_TRIGGERE
D: Unit down reason: software
triggered
Informational Unit went down due to software
triggered reset.
No action required.
%EQM_UNIT_CRASHED: Unit
down reason: unit crashed
Informational Unit went down due to unit crash. No action required.
%EQM_UNKNOWN: Unit down
reason: unknown
Informational Unit went down due to unknown reason. No action required.
%EQM_LPC_FAULT: LPC bus
error
Critical Fault detected due to LPC bus error. Contact support team for
RMA process.
%EQM_MEDIA_TEMP_HIGH:
Media high temperature threshold
crossed major warning
Critical Digital Optical Monitoring detects that
the high temperature major threshold is
crossed.
Check fan units and check
whether the media type is
supported. Try replacing the
media.
%EQM_MEDIA_TEMP_HIGH_W
ARNING: Media high warning
temperature threshold crossed
minor warning
Warning Digital Optical Monitoring detects that
the high temperature minor threshold is
crossed.
Check fan units and check
whether the media type is
supported. Try replacing the
media.
%EQM_MEDIA_TEMP_LOW_WA
RNING: Media low warning
temperature threshold crossed
minor warning
Warning Digital Optical Monitoring detects that
the low temperature minor threshold is
crossed.
Check fan units and check
whether the media type is
supported. Try replacing the
media.
%EQM_MEDIA_TEMP_LOW:
Media low temperature threshold
crossed major warning
Critical Digital Optical Monitoring detects that
the low temperature major threshold is
crossed.
Check fan units and check
whether the media type is
supported. Try replacing the
media.
%EQM_MEDIA_VOLTAGE_HIGH
: Media high voltage threshold
crossed major warning
Critical Digital Optical Monitoring detects that
the high voltage major threshold is
crossed.
Check fan units and check
whether the media type is
supported.. Try replacing the
media.
%EQM_MEDIA_VOLTAGE_HIGH
_WARNING: Media high warning
voltage threshold crossed minor
warning
Warning Digital Optical Monitoring detects that
the high voltage minor threshold is
crossed.
Check whether the media is
supported. Try replacing the
media.
34 EQM system log message reference