Users Guide

Table Of Contents
EQM system log message reference
This section lists the system log messages that are generated by the EQM process.
Table 15. EQM system log messages
System log message Severity Description Recommended action
%EQM_UNIT_UP: Unit is up Informational Equipment Manager declared the card is
ready.
No action required.
%EQM_UNIT_DOWN: Unit is
down
Critical Equipment Manager detected the card is
reset.
No action required.
%EQM_UNIT_PWRON: Unit
powered-on
Informational Equipment Manager detected the card is
powered on and it is in the process of
check-in.
No action required.
%EQM_UNIT_RESET: Unit is
being reset
Informational Equipment Manager detected the card is
checked-in after reset.
No action required.
%EQM_UNIT_DETECTED: Unit
present
Informational Equipment Manager detected the card. No action required.
%EQM_UNIT_CHECKIN: Unit
check-in detected
Informational Equipment Manager identified the
specific card-type and the system ports.
No action required.
%EQM_UNIT_RETRY_RESET:
Unit power cycled reload
Informational Equipment Manager retrying reset due to
some problem detected.
No action required.
%EQM_UNIT_SHUTDOWN: Unit
shut down
Critical Equipment Manager forcing shutdown on
the card due to some problem.
Check for other alarms
related to temperature etc.
%EQM_UNIT_NO_CHECKIN:
Unit not check-in
Warning Equipment Manager does not detect the
card checked-in.
Check for any service
failures in the system.
%EQM_SYSTEM_RELOAD: User
request to reload system
Informational Reboot has been initiated by user. No action required.
%EQM_PSU_DETECTED: Power
supply unit present
Informational PSU has been detected. No action required.
%EQM_PSU_OFF: Power supply
unit power off or removed
Critical PSU has been removed or power has
been turned off for the PSU.
If not expected, check the
PSU and the power-source
for any loose contacts, or
loss of power.
%EQM_FAN_TRAY_DETECTED:
Fan tray present
Informational Fan Tray has be detected. No action required.
%EQM_FAN_TRAY_OFF: Fan
tray power off or removed
Critical Fan tray has been removed. If not expected, check for
any loose contacts or device
not being seated properly.
%EQM_PAS_NOT_READY: PAS
service is not ready
Critical PAS service has not yet come up. Check if PAS has crashed.
Typically system will reboot
after some time.
%EQM_TML_WARN_CROSSED:
Thermal threshold crossed
warning
Warning One of the temperature sensors has
crossed the "Warning Threshold".
Check the environment, any
fan trays being faulty etc.
The fans speeds will increase
automatically.
16
32 EQM system log message reference