Reference Guide

Table Of Contents
Command Mode EXEC
Usage Information In an iSCSI session, Target is the storage device, and Initiator is the server connected to the storage device.
Example
OS10# show iscsi session
Example (detailed)
OS10# show iscsi session detailed
Session 1
------------------------------------------------
Target:iqn.2001-05.com.equallogic:0-8a0906-00851a00c-98326939fba510a1-517
Initiator:iqn.1991-05.com.microsoft:win-rlkpjo4jun2
Up Time:00:00:18:12(DD:HH:MM:SS)
Time for aging out:29:23:59:35(DD:HH:MM:SS)
ISID:400001370000
Initiator Initiator Target Target Connection
IP Address TCP Port IP Address TCP Port ID
----------------------------------------------------------
10.10.10.210 54748 10.10.10.40 3260 1
Session 2
------------------------------------------------
Target:iqn.2001-05.com.equallogic:0-8a0906-01251a00c-8ab26939fbd510a1-518
Initiator:iqn.1991-05.com.microsoft:win-rlkpjo4jun2
Up Time:00:00:16:02(DD:HH:MM:SS)
Time for aging out:29:23:59:35(DD:HH:MM:SS)
ISID:400001370000
Initiator Initiator Target Target Connection
IP Address TCP Port IP Address TCP Port ID
----------------------------------------------------------
10.10.10.210 54835 10.10.10.40 3260 1
Supported Releases 10.3.0E or later
show iscsi storage-devices
Displays information about the storage arrays directly attached to OS10 ports.
Syntax
show iscsi storage-devices
Parameters None
Command Mode EXEC
Usage Information The command output displays the storage device connected to each switch port and whether iSCSI automatically
detects it.
Example
OS10# show iscsi storage-devices
Interface Name Storage Device Name Auto Detected Status
-----------------------------------------------------------
ethernet1/1/23 EQL-MEM true
Supported Releases 10.3.0E or later
Converged network DCB example
A converged data center network carries multiple trac types (SAN, server, and LAN) that are sensitive to dierent aspects of data
transmission. For example, storage trac is sensitive to packet loss, while server trac is latency-sensitive. In a single converged link, all
trac types coexist without imposing serious restrictions on others' performance. DCB allows iSCSI and FCoE SAN trac to co-exist with
server and LAN trac on the same network. DCB features reduce or avoid dropped frames, retransmission, and network congestion.
566
Converged data center services