Connectivity Guide

Table Of Contents
Supported
Releases
10.4.0E(R1) or later
fcoe-pinned-port
Marks a port as a pinned port in the port-channel. This configuration is supported on FSB, Ethernet LAG in NPG, and F_Port
mode. It is not supported on a VLTi LAG.
Syntax
fcoe-pinned-port
Parameters node/slot/port[:subport]Enter the interface type details.
Defaults Disabled
Command Mode Port-channel INTERFACE
Usage
Information
You can configure only single port per port-channel. If the port is not configured properly, or if the pinned
port goes down, the other ports in the port-channel are not used even if the ports have valid path to
server. The no version of this command removes the pinned port configuration.
Example
OS10(conf-if-eth-1/1/9)# channel-member 10
OS10(conf-if-eth-1/1/9)# fcoe-pinned-port
Warning: Any existing FCoE session in port-channel will get cleared. Do
you want to continue(yes/no)?yes
Supported
Releases
10.4.2.0 or later
fcoe max-sessions-per-enodemac
Configures the maximum number of sessions allowed for an ENode.
Syntax
fcoe max-sessions-per-enodemac max-session-number
Parameters max-session-number Enter the maximum number of sessions to be allowed, from 1 to 64.
Defaults 32
Command Mode CONFIGURATION
Usage
Information
The no version of this command resets the number of sessions to the default value.
Example
OS10(config)# fcoe max-sessions-per-enodemac 64
Supported
Releases
10.4.0E(R1) or later
fcoe priority-bits
Configures the priority bits for FCoE application TLVs.
Syntax
fcoe priority-bits priority-value
Parameter priority-value Enter PFC priority value advertised in FCoE application TLV. You can enter one of
the following values: 0x01, 0x02, 0x04, 0x08, 0x10, 0x20, 0x40, or 0x80.
Default 0x08
Command Mode CONFIGURATION
Usage
Information
You can configure only one PFC priority at a time. The no version of this command returns the
configuration to default value.
238 Fibre Channel