Connectivity Guide

Table Of Contents
Table 5. DOM Alarms (continued)
Alarm Category Alarm Name Traps Generated? Severity Level
Temperature low
warning
N Minor
Voltage Voltage high Y Major
Voltage high
warning
N Minor
Voltage low Y Major
Voltage low warning N Minor
Bias Bias high Y Major
Bias high warning N Minor
Bias low Y Major
Bias low warning N Minor
Power transmission
(Tx)
Tx high Y Major
Tx high warning N Minor
Tx low Y Major
Tx low warning N Minor
Power reception
(Rx)
Rx high Y Major
Rx high warning N Minor
Rx low Y Major
Rx low warning N Minor
You can enable or disable the DOM feature, configure traps, and view the DOM status.
Enable DOM and DOM traps
To generate DOM alarms, do the following.
1. Enable DOM.
OS10(config)# dom enable
2. Enable DOM traps.
OS10(config)# snmp-server enable traps dom
You can run the show alarms command in EXEC mode to view any alarms that are generated.
View DOM alarms
OS10# show alarms
Index Severity Name Raise-time Source
----- -------- ------------------- ----------------------- ------
0 major EQM_MEDIA_TEMP_HIGH Tue 06-04-2019 12:32:07 Node.1-Unit.1
View DOM event log message
The following are examples of event logs:
High temperature warning:
Aug 03 06:35:47 OS10 dn_eqm[9135]: [os10:alarm], %Dell EMC (OS10)
%EQM_MEDIA_TEMP_HIGH: Media high temperature threshold crossed major warning
164