Connectivity Guide

Table Of Contents
Up Time : 2 days 05:57:17
-- Unit 1 --
Status : up
System Identifier : 1
Down Reason : unknown
Digital Optical Monitoring : disable
System Location LED : off
Required Type : S4048
Current Type : S4048
Hardware Revision : X01
Software Version : 10.4.3.0
Physical Ports : 48x10GbE, 6x40GbE
BIOS : 3.21.0.4
System CPLD : 15
Master CPLD : 12
Slave CPLD : 5
-- Power Supplies --
PSU-ID Status Type AirFlow Fan Speed(rpm) Status
----------------------------------------------------------------
1 not-present
2 up UNKNOWN NORMAL 1 10704 up
-- Fan Status --
FanTray Status AirFlow Fan Speed(rpm) Status
----------------------------------------------------------------
1 up NORMAL 1 10108 up
2 10069 up
2 up NORMAL 1 9954 up
2 10108 up
3 up NORMAL 1 9867 up
2 9867 up
Diagnostic commands
location-led interface
Changes the location LED of the interface.
Syntax
location-led interface ethernet {chassis/slot/port[:subport]} {on | off}
Parameters
chassis/slot/port[:subport] Enter the ethernet interface number.
on | off Set the interface LED to be on or off.
Default Not configured
Command Mode EXEC
Usage
Information
Use this command to change the location LED for the specified interface.
Example
OS10# location-led interface ethernet 1/1/1 on
OS10# location-led interface ethernet 1/1/1 off
Supported
Releases
10.3.0E or later
Troubleshoot OS10 1105