Known Issues
* When you uninstall the Dell SPI, the following error may display:
"The Setup must update files or services not updateable while the system is running. If you
choose to continue, a reboot is required to complete the setup."
You can ignore this error as the uninstallation of the Dell SPI is successful.
* When you uninstall the Dell SPI, the following error is displayed on the HPOM console:
"MMC has detected an error in a snap-in. It is recommended that you shut down and restart
MMC."
When this error occurs, you must close the HPOM console and launch it again.
* The Dell SPI does not support a multi-valued pattern for the fully qualified domain name
(FQDN), IP Address, and Node name for external nodes and managed nodes.
For example, if you have an IP address pattern like 10.44.176.100 and 10.44.176.10 to group
and monitor nodes, the Dell SPI does not recognize the pattern which may result on alerts
not receiving on correct nodes.
* You cannot launch the Dell SPI tools from a HP Operations Manager remote console.
* If the servers are already grouped under Dell Managed Systems and are not reachable
before the SNMP timeout value expires, then the Global Health Status is displayed as critical
against the servers.
* The Dell SPI configurator utility stores and retrieves 'snmptimeout' values only in multiples
of 10.
* When the Auto-grouping policy is scheduled with other Monitoring policies at the same
time, an error message in a pop-up window may be displayed. You can ignore the error
message by clicking OK in the pop-up window.
* Dell Compellent SNMPv2 traps are not associated to the Compellent Management IP
classified in the HPOM console.
* SNMPv2 iDRAC7 Test Trap is not supported in HPOM Management Server.
* For Compellent trap Id 206 (Enclosure Status change) having severity “Informational”, “$10”
will be displayed in the trap text field of the HPOM Console.