Owner's Manual

Instrumentation Traps
This section describes the traps that are generated by the Instrumentation service of the Server Administrator. All the
traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.1
For information on the description of the traps, see the
Instrumentation Traps
section in the
Dell OpenManage Server
Administrator Version 7.1 SNMP Reference Guide.
Miscellaneous Traps
The following lists the Miscellaneous traps that informs you that certain alert systems are up and working.
Table 1. Miscellaneous Traps
Trap ID Alert Name Related Alerts That Are Cleared
1001 System Up None
1004 Thermal Shutdown None
1006 Automatic System Recovery None
1007 Host System Reset None
1013 System Peak Power New Peak None
Temperature Probe Traps
Temperature probes help protect critical components by alerting the systems management console when temperatures
become too high inside a chassis. The temperature probe traps use additional variables: sensor location, chassis
location, previous state, and temperature sensor value reported in degrees Celsius.
Table 2. Temperature Probe Traps
Trap ID Alert Name Related Alerts That Are Cleared
1052 Temperature Probe Normal TemperatureProbeWarning (1053),
TemperatureProbeFailure (1054),
TemperatureProbeNonRecoverable
(1055)
1053 Temperature Probe Warning TemperatureProbeFailure (1054),
TemperatureProbeNonRecoverable
(1055)
1054 Temperature Probe Failure TemperatureProbeWarning (1053),
TemperatureProbeNonRecoverable
(1055)
1055 Temperature Probe Nonrecoverable TemperatureProbeWarning (1053),
TemperatureProbeFailure (1054)
Cooling Device Traps
Cooling device traps monitor how well a fan is functioning.
6