Owner's Manual

Installation and Configuration Notes
For information on installing the Dell Smart Plug-in (Dell SPI) for HP Operations Manager 9.0 for Windows, refer the "Dell
Smart Plug-in for HP Operations Manager 9.0 for Microsoft Windows Version 3.0 Installation Guide".
Upgrade
If you have Dell SPI version 2.0 or 2.1 installed on the management server, you can upgrade the same to version 3.0.
For more information on Upgrade, refer the "Dell Smart Plug-in for HP Operations Manager 9.0 Version 3.0 for Microsoft
Windows Installation Guide".
Uninstallation
For information on uninstalling the Dell Smart Plug-in (Dell SPI) for HP Operations Manager 9.0 for Windows, refer the "Dell
Smart Plug-in for HP Operations Manager 9.0 Version 3.0 for Microsoft Windows Installation Guide".
Open Issues and Resolutions
Fixed Issu es/def
When you uninstall the Dell SPI, the following error may be displayed:The Setup must update files or services
that cannot be updated while the system is running. If you choose to continue, a reboot will be required to
complete the setup". You can ignore this error as the uninstallation of the Dell SPI is successful.
When you uninstall the Dell SPI, the following error is displayed on the HPOM console: "MMC has detected an error
in a snap-in. It is recommended that you shut down and restart MMC. When this error occurs, you must close the
HPOM console and re-launch it again.
The Dell SPI does not support a multi-valued pattern for the fully qualified domain name (FQDN), IP Address, and
Node name, for the external nodes.
For example, if you provide an IP address pattern like 10.44.176.* to group and monitor nodes within that range,
the Dell SPI does not recognize the pattern.
You cannot launch the Dell SPI tools from a HP Operations Manager remote console.
If the servers are already grouped under Dell Managed Systems and are not reachable before the SNMP timeout
value expires, then the Global Health Status is displayed as critical against the servers.
The Dell SPI configurator utility stores and retrieves 'snmptimeout' values only in multiples of 10.
In the HPOM Console, the following Dell 12G out-of-band server Traps are displayed with Message Object as
"DellOOBServer" instead of respective object names.
Traps affected:
o
Battery Object Traps
BAT1000 : Battery on <controller name> is missing.
BAT1008 : Write policy on <controller name> was changed to Write Through.
BAT1021 : The charge level for the battery on <controller name> is below the normal
threshold.
BAT1024 : Errors detected with battery on <controller name>.