10 Trap Correlation
Memory Device Traps
Memory device messages provide status and warning information for memory
modules present in a particular system. Memory devices determine health
status by counting the number of ECC memory corrections.
NOTE: A value of failure or non-recoverable does not indicate a system
failure or loss of data, but rather that the specified system exceeded the specified
ECC correction threshold.
Fan Enclosure Traps
Some systems are equipped with a protective enclosure for fans. Fan
enclosure traps monitor enclosures for whether foreign objects are present
and for how long a fan enclosure is absent from a chassis.
Table 2-9. Memory Device Messages
Trap
ID
Alert Name Related Alerts that are Cleared
1403 MemoryDeviceWarning MemoryDeviceFailure (1404),
MemoryDeviceNonRecoverable (1405)
1404 MemoryDeviceFailure MemoryDeviceWarning (1403)
MemoryDeviceNonRecoverable (1405)
1405 MemoryDeviceNonRecoverable MemoryDeviceFailure (1404)
MemoryDeviceWarning (1403)
Table 2-10. Fan Enclosure Traps
Trap
ID
Alert Name Related Alerts that are Cleared
1452 Fan Enclosure Insertion FanEnclosureRemoval (1453),
FanEnclosureExtendedRemoval (1454)
1453 Fan Enclosure Removal FanEnclosureExtendedRemoval (1454)
1454 Fan Enclosure Extended Removal FanEnclosureRemoval (1453)
book.book Page 10 Thursday, January 28, 2010 7:09 PM