14 Scaling VCF Domains Beyond a Single MX7000 Chassis | Document ID
• All MX7000 chassis in the same Scalable Fabric must be in the same Multichassis Group.
• Mixing IOM types in the same Scalable Fabric (for example, MX9116n FSE in fabric slot A1 and
MX5108n in fabric slot A2) is not supported.
• All participating MX9116n FSEs and MX7116n FEMs must be in MX7000 chassis that are part of the
same MCM group. For more information, see the Dell EMC OpenManage Enterprise-Modular Edition
Version 1.20.00 for PowerEdge MX7000 Chassis User's Guide. Find the relevant version of the User
Guide in the OME-M and OS10 compatibility and documentation table.
• When using both Fabric A and B for a Scalable Fabric, the following restrictions apply:
- IOM placement for each fabric must be the same in each chassis. For instance, if an MX9116n
FSE is in chassis 1 fabric slot A1, then the second MX9116n FSE should be in chassis 2 fabric
slot A2.
- For chassis 3 through 10, which only contain MX7116n FEMs, they must connect to the MX9116n
FSE that is in the same group.